INSTAGLOW is a dry dispersion for polishing of solid dosage forms. It can be reconstituted in aqueous as well as organic solvent systems. The product imparts gloss to solid dosage forms, especially to coated tablets.
Features | Benefits |
---|---|
|
|
|
|
|
|
|
|
|
|
|
|
All products are checked for the regulatory compliance of all ingredients in the target countries and market segments of sale. This determination is made at the time the initial formulation is established, based on customer-supplied information. If market countries and/or segments are extended once the formulation has been established, customers are encouraged to contact us to ensure that regulatory compliance is not compromised.
Purified water at up to 7% w/w solids
Organic: IPA 35% + MDC 65% w/w at up to 5% solids
Hydro-alcoholic: Water 15% + IPA 85% w/w at up to 5% solids
Variable-speed mechanical stirrer
Mixing Vessel
Determine the quantities of Instaglow (7% w/w solids) and water required based on the quantity of tablets to be coated and the target coating weight gain. e.g.: For coating 1.0 kg of tablets to 0.2% wt. gain, weigh 2.2 g Instaglow and 29.2 gm purified water at room temperature (includes 10% overage for losses)
Determine the quantities of Instaglow (5% w/w solids) and IPA 35% + MDC 65% required based on the quantity of tablets to be coated and the target coating weight gain. e.g.: For coating 1.0 kg of tablets to 0.2% wt. gain, weigh 2.2 g Instaglow and 41.8 gm IPA 35%+ MDC 65% at room temperature (includes 10% overage for losses)
Determine the quantities of Instaglow (5% w/w solids) and Water 15% + IPA 85% required based on the quantity of tablets to be coated and the target coating weight gain. e.g.: For coating 1.0 kg of tablets to 0.2% wt. gain, weigh 2.2 g Instaglow and 41.8 gm Water 15% + IPA 85% at room temperature (includes 10% overage for losses)
Instaglow (Aqueous)
Add the weighed quantity of water to a mixing vessel.
Using a mechanical stirrer, stir the purified water to form a vortex.
Add required quantity of Instaglow to the centre of the liquid vortex in a slow steady stream, avoiding clumping while maintaining a vortex. Once the entire quantity of Instaglow has been added, reduce the stirrer speed to eliminate the vortex. (Fig. 2) Continue mixing for 45 minutes.
Instaglow (Organic)
Add the weighed quantity of organic solvent to a mixing vessel.
Using a mechanical stirrer, stir the organic solvent to form a vortex.
Add required quantity of Instaglow to the centre of the liquid vortex in a slow steady stream, avoiding clumping while maintaining a vortex. Once the entire quantity of Instaglow has been added, reduce the stirrer speed to eliminate the vortex. (Fig. 3) Continue mixing for 45 minutes.
Instaglow (hydro alcoholic)
Add the weighed quantity of hydro alcoholic solvent to a mixing vessel.
Using a mechanical stirrer, stir the hydro alcoholic solvent to form a vortex.
Add required quantity of Instaglow to the centre of the liquid vortex in a slow steady stream, avoiding clumping while maintaining a vortex. Once the entire quantity of Instaglow has been added, reduce the stirrer speed to eliminate the vortex. (Fig. 4) Continue mixing for 45 minutes.
Side-vented (fully perforated) pans | Side-vented (fully perforated) pans | |
---|---|---|
Pan diameter (inch) | 24-60 | 12-36 |
Tablet load (kg) | 10-300 | 0.5-50 |
Weight gain (%) | 0.2% | |
Number of guns | 1-6 | 1 |
Liquid nozzle diameter (mm) | 1.0-1.2 | |
Atomising air pressure (bar) | 2.5-3.5 | |
Pattern air pressure | To achieve maximum uniform bed coverage | |
Tablet bed temperature, Aqueous (⁰C) | 40-45 | |
Tablet bed temperature, Organic (⁰C) | 34-38 | |
Tablet bed temperature, Hydro-alcoholic (⁰C) | 36-40 | |
Inlet air temperature (⁰C) | Set to achieve required product bed temperature | |
Suspension spray rate | Set to achieve required product bed temperature | |
Exhaust air volume | To maintain slight negative pressure in pan | |
Pan speed | Minimum for steady tablet flow through spray zone |
*Tablet bed temperature offers the most effective way of controlling the coating process. Where this measurement is unavailable, exhaust temperature may be substituted. However, the relationship between the two measurements is complex and depends on several factors such as pan load, pan depression, pan design and airflow rate. Indicated exhaust temperature may be above or below the true bed temperature. It is recommended that the relationship between the two measurements is calibrated.
HPMC; PEG 6000; Glycerine; PVA; Glidant.